by HeyheyL | Mar 19, 2020 | Analyzer, Application, Chromium VI, Galvanization, Measuring value, Parameters, Product, Water treatment
The Testomat 2000® CrVI 0-5 ppm process photometer is the further development of the Testomat 2000® CrVI device with a larger measuring range. You can monitor a chromate content (CrO42-) of 0 to 11.15 ppm, or hexavalent chromium (CrVI) within the range of 0 to 5.0...
by HeyheyL | Mar 19, 2020 | Analyzer, Application, Chromium VI, Galvanization, Measuring value, Parameters, Product, Water treatment
The Testomat 2000® CrVI process photometer is a robust wet-chemical online monitor used to monitor chromate content (CrO42-) within the range of 0 to 2.0 mg/l, or hexavalent chromium (CrVI) within the range of 0 to 1.0 mg/l. The device operates with a photometric...
by HeyheyL | Mar 19, 2020 | Analyzer, Application, Bromine, Drinking water supply, Galvanization, Measuring value, monitoring disinfectant dosing, Parameters, Product, Water treatment
The process photometer Testomat 2000® Br is a wet-chemical online instrument for monitoring the content of bromine (Br2) in the 0–5.6 mg/l (ppm) range. Application Monitoring the dosing of disinfectants Measuring range 0 – 2.23 mg/l (ppm) (resolution...
by HeyheyL | Mar 19, 2020 | 0,05 - 0,5°dH, 0,25 - 2,5°dH, 0,5 – 5°dH, 1,0 – 20,0°dH, 1,00 - 10,00°dH, 2,50 - 25,00°dH, Analyzer, Application, Boiler houses, Carbonate hardness (alkalinity), Cooling towers, Decarbonisation, Drinking water supply, Galvanization, Hospitals, Measuring value, Osmosis systems, Parameters, Product, Swimming pools, Water hardness, Water softening, Water treatment
The Testomat2000® CN DUO is, just like the Testomat 2000® CN, and ideal instrument for monitoring the water quality of water treatment, water blending and drinking-water plant. The operating menu is in mandarin or english. Application use in two circuits with...
by HeyheyL | Mar 19, 2020 | 0,05 - 0,5°dH, 0,25 - 2,5°dH, 0,5 – 5°dH, 1,0 – 20,0°dH, 1,00 - 10,00°dH, 2,50 - 25,00°dH, Analyzer, Application, Boiler houses, Carbonate hardness (alkalinity), Cooling towers, Decarbonisation, Drinking water supply, Galvanization, Hospitals, Measuring value, Osmosis systems, Parameters, Product, Swimming pools, Water hardness, Water softening, Water treatment
The Testomat 2000® DUO is a special design of the Testomat 2000®.You can measure 2 different parameters simultaneously, e.g. 2 measuring ranges for water hardness or water hardness and alkalinity. The monitoring of 2 measuring points is possible and there is an...
by HeyheyL | Mar 19, 2020 | 0,05 - 0,5°dH, 0,25 - 2,5°dH, 0,5 – 5°dH, 1,0 – 20,0°dH, 1,00 - 10,00°dH, 2,50 - 25,00°dH, Analyzer, Application, Boiler houses, Carbonate hardness (alkalinity), Cooling towers, Decarbonisation, Drinking water supply, Galvanization, Measuring value, Osmosis systems, Parameters, Product, Swimming pools, Water hardness, Water softening, Water treatment, with antioxidant dosing
Concentrations of oxidising agents, such as chlorine, chlorine dioxide or ozone, above TVO-approved (German drinking water ordinance) limit values have a detrimental effect on the dye contained in Testomat 2000® reagents. Exact determination of the water hardness is...