The process photometer Testomat® Modul NH2CL (monochloramine) is a robust, wet chemical online measuring converter for monitoring the decay behaviour in cooling towers after shock chlorination.
The Testomat® Modul NH2CL then transmits the measurement result to the control system:

  • via a 4-20 mA interface as a current value. The control system calculates the measurement value from the current, e.g. in ppm.
  • via a RS232 interface as a measurement value.

The measurement converter combines the measuring technology of the Testomat® family and a reduced technical design, which lowers costs and maintenance effort.

Settings can be displayed and changed with the Service Monitor programme, which is delivered with the device.
 

Application

  • Monitoring of the decay behaviour in cooling towers after shock chlorination

 
Measuring range

0 – 5 ppm (resolution 0.1)
 

Technical Data

Power supply: 24 VDC, the device is protected against reverse polarity
Power consumption: max. 1 A, without external load
Protection class: II
Degree of protection: IP 54
Ambient temperature: 10–40 °C
Dimensions (B x H x T): 270x 350 x 147 mm
Weight: approx. 5.3 kg
Relay contact load: max. 35 VAC / 60 DC, max. 4 A
Current interface: 0/4 – 20 mA, max. load 500 Ohms
USB interface: Type Mini-B (connector); USB 2.0 Full speed
SD card: SD or SDHC cards with a maximum capacity of 32GByte are suitable. The card must be FAT or FAT32 formatted.
Battery: Lithium CR2032
 

Mains water supply

Operating pressure:
1 to 8 bar or
0,3 to 1 bar after removing of the valve body out of the regulator/filter housing
Water inlet: Opaque hose with 6 mm external diameter/4 mm internal diameter
Water outlet: Hose with 12 mm internal diameter
Water temperature: 10 to 40 °C

Here you will find available reagents for the Testomat® Modul NH2CL