{"id":2093,"date":"2020-03-19T08:20:25","date_gmt":"2020-03-19T07:20:25","guid":{"rendered":"http:\/\/heylanalysis.de\/?p=2093"},"modified":"2022-02-28T15:53:43","modified_gmt":"2022-02-28T14:53:43","slug":"testomat-eco-c","status":"publish","type":"post","link":"https:\/\/heylanalysis.de\/en\/testomat-eco-c\/","title":{"rendered":"Testomat ECO\u00ae C"},"content":{"rendered":"\n<div class=\"wp-block-image\"><figure class=\"alignleft is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/heylanalysis.de\/wp-content\/uploads\/2020\/03\/Testomat_ECO-Vorschau.jpg\" alt=\"\" class=\"wp-image-6714\" width=\"302\" height=\"302\" srcset=\"https:\/\/heylanalysis.de\/wp-content\/uploads\/2020\/03\/Testomat_ECO-Vorschau.jpg 403w, https:\/\/heylanalysis.de\/wp-content\/uploads\/2020\/03\/Testomat_ECO-Vorschau-150x150.jpg 150w, https:\/\/heylanalysis.de\/wp-content\/uploads\/2020\/03\/Testomat_ECO-Vorschau-300x300.jpg 300w\" sizes=\"(max-width: 302px) 100vw, 302px\" \/><\/figure><\/div>\n\n\n\n<p>The <strong>Testomat ECO\u00ae<\/strong> C determines alkalinity or acid capacity fully automatically via titration.<\/p>\n\n\n\n<p>It is ideal for monitoring and controlling the water quality of  community swimming pools. With online monitoring the raising of  alkalinity is fully automatic.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">&nbsp;<br>Application<\/h4>\n\n\n\n<ul class=\"wp-block-list\"><li>community swimming pools<\/li><li>water treatment plants<\/li><li>drinking water plants<\/li><\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">&nbsp;<br>Measuring range<\/h4>\n\n\n\n<p>alkalinity (carbonate hardness) \/ acid capacity<br>0,5-10,0 \u00b0dH \/ 1,0-20,0\u00b0dH<br>0,18-3,58 mmol\/l \/ 0,30-7,16 mmol\/l (indicator TC 2050 with extended measuring range)<br>(depending on the choice of the indicator)<br>&nbsp;<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Technical Data<\/h4>\n\n\n\n<p><strong>Power supply:<\/strong> 230\u2013240 VAC, 115 VAC, 24 VAC all 50\u201360Hz<br> <strong>Power consumption:<\/strong> max. 30 VA<br> <strong>Protection class:<\/strong> I <br><strong>Degree of protection:<\/strong> IP 65<br><strong>Ambient temperature:<\/strong>&nbsp;10\u201345 \u00b0C<br><strong>Option<\/strong>: booster pump see accessories<br><strong>Dimensions<\/strong> (B x H x T): 380 x 480 x 280 mm<br> <strong>Weight<\/strong>: approx. 9 kg<br><strong>Menu languages<\/strong>: German, English<br>&nbsp;<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Mains water supply<\/h4>\n\n\n\n<p><strong>Operating pressure<\/strong>: <br>1 to 8 bar or <br>0,3 to 1 bar <br>after removing of the valve body out of the regulator\/filter housing<br><strong>Water inlet:<\/strong> Opaque hose with 6 mm external diameter\/4 mm internal diameter<br><strong>Water outlet:<\/strong> Hose with 6 mm external diameter\/4 mm internal diameter<br><strong>Water temperature:<\/strong> 10 to 40 \u00b0C<br><br>Here you will find <a href=\"https:\/\/heylanalysis.de\/en\/testomat-2000-indikatoren\/\">available indicators<\/a> for the <strong>Testomat ECO\u00ae C<\/strong>.<br>Select accessories in the <a href=\"https:\/\/heylanalysis.de\/en\/products\/\">product search<\/a> to find e.g. pumps, filters and service sets for the <strong>Testomat ECO\u00ae C<\/strong>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Testomat ECO\u00ae C determines alkalinity or acid capacity fully automatically via titration. It is ideal for monitoring and controlling the water quality of community swimming pools. With online monitoring the raising of alkalinity is fully automatic. &nbsp;Application community swimming pools water treatment plants drinking water plants &nbsp;Measuring range alkalinity (carbonate hardness) \/ acid capacity0,5-10,0 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":6741,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"off","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[535,536,497,511,517,532,520,513,525,516,499,523,530,496,524,515,528],"tags":[],"class_list":["post-2093","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-05-5dh-en","category-10-200dh-en","category-analyzer","category-application","category-boiler-houses","category-carbonat-hardness","category-cooling-towers","category-decarbonisation","category-drinking-water-supply","category-galvanization","category-measuring-value","category-osmosis-systems","category-parameters","category-product","category-swimming-pools","category-water-softening","category-water-treatment"],"_links":{"self":[{"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/posts\/2093","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/comments?post=2093"}],"version-history":[{"count":5,"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/posts\/2093\/revisions"}],"predecessor-version":[{"id":13829,"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/posts\/2093\/revisions\/13829"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/media\/6741"}],"wp:attachment":[{"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/media?parent=2093"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/categories?post=2093"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/heylanalysis.de\/en\/wp-json\/wp\/v2\/tags?post=2093"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}